PPA109S Emergency Lighting & Additional Bridges
Video Tutorial: Watch the companion video V38: PPA109S Emergency Lighting & Additional Bridges for a visual walkthrough.
Overview
The Keilton+autani system includes specialized devices for emergency lighting control, building system integration, and mesh network extension. This article covers the PPA109S Emergency Controller, CR04 Inter-Op Bridge, BG01 485 Bridge, and RP0 Signal Booster.
PPA109S Emergency Lighting Controller
The PPA109S is a UL924-compliant Emergency Lighting Control Device that works with Keilton smart lighting controllers.
Features
| Feature | Description |
|---|---|
| Compliance | UL924 certified |
| Function | Automatic emergency lighting response |
| Integration | Works with Keilton controllers |
| Configuration | Power fail and restore actions |
Adding the PPA109S
- Navigate to More → Device Info.
- Tap Click to Add.
- Select the PPA109S when it appears.
- Tap Add to confirm.
Configuring the PPA109S
- On the Device Info page, long press the PPA109S icon.
- The configuration page opens.
- Tap the device name to rename (optional).
Power Failure Action
Configure what happens when normal power fails:
| Option | Description |
|---|---|
| 100% All Lights | Default - All lights to full brightness |
| Scene | Activate a specific emergency scene |
| Group + Level | Set specific group to specific level |
Power Restore Action
Configure what happens when normal power returns:
| Option | Description |
|---|---|
| None | Default - No action |
| Scene | Activate a specific scene |
| Group + Level | Set group to level (including Auto) |
Repeat Interval
Set a repeat interval to periodically reapply the emergency command. This prevents luminaires from accidentally dimming during emergency situations.
CR04 Inter-Op Bridge
The CR04 connects your Keilton system to external building automation and demand response systems.
Use Cases
- Building management system integration
- Demand response program participation
- Third-party control system connectivity
Adding the CR04
- Plug the CR04 into a USB port.
- Navigate to More → Device Info.
- Tap Select to Add.
- Select and add the CR04.
Documentation
For detailed setup: - CR04 Inter-Op Bridge User's Guide - Demand Response Instructions
Available at: https://www.litetrace.com/resource
BG01 485 Bridge
The BG01 provides RS-485 communication capability for integration with industrial protocol systems.
Use Cases
- Building automation controller integration
- Energy management systems
- Industrial control equipment
Adding the BG01
- Navigate to More → Device Info.
- Tap Click to Add.
- Select the BG01 when it appears.
- Add to your zone.
Documentation
Refer to: BG01 485 Bridge Instructions
RP0 Signal Booster
The RP0 extends mesh network coverage in challenging environments where wireless signals may not reach all fixtures reliably.
When to Use
- Large spaces with distant fixtures
- Areas with signal-blocking obstacles
- Installations with weak mesh connectivity
- Spaces with concrete or metal barriers
Adding the RP0
- Plug the RP0 into a USB port.
- Navigate to More → Device Info.
- Tap Select to Add.
- Select and add to your zone.
Critical: Zone Association
Important: The RP0 must be added to the zone being commissioned.
When moving to commission a different zone: 1. Delete the RP0 from the current zone 2. Add it to the next zone
The RP0 extends coverage only for the zone it's associated with.
Placement
Position the RP0 strategically between: - The main mesh network (well-connected fixtures) - Distant or poorly-connected fixtures
Adding Devices Summary
All these devices are added via:
- More page
- Device Info
- Click to Add or Select to Add
- Select device when it appears
- Add to zone
Documentation Resources
| Device | Documentation |
|---|---|
| PPA109S | PPA109S Instruction Guide |
| CR04 | CR04 Inter-Op Bridge User's Guide, Demand Response Instructions |
| BG01 | BG01 485 Bridge Instructions |
| RP0 | RP0 Commissioning Guide |
Resources available at: https://www.litetrace.com/resource
Troubleshooting
| Issue | Device | Solution |
|---|---|---|
| Device not appearing | All | Check USB power/connection |
| Emergency action not working | PPA109S | Verify configuration and test |
| Integration not responding | CR04/BG01 | Check external system configuration |
| Coverage still poor | RP0 | Reposition or add additional boosters |
| RP0 not helping other zone | RP0 | Delete and re-add to correct zone |
Quick Reference
| Device | Function | Add From |
|---|---|---|
| PPA109S | Emergency lighting | Device Info |
| CR04 | Building automation | Device Info |
| BG01 | RS-485 integration | Device Info |
| RP0 | Signal extension | Device Info |
Related Articles
Based on Keilton+autani App User Guide v9.7